Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
61. BURNER FLAME Gas Models
Refer to Figure 38
a. Close loading door, start the dryer in a heat
setting (refer to the Operating Instructions
supplied with the dryer); the dryer will start, the
igniter will glow red and the main burner will
ignite.
b. Allow dryer to operate for approximately five
minutes, then open the access door and loosen
the air shutter lockscrew.
c. Turn air shutter to the right or left to obtain a
soft, uniform blue flame. (A lazy, orange-
tipped flame indicates lack of air. A harsh,
roaring, very blue flame indicates too much
air.)
d. After proper flame is obtained, tighten air
shutter lockscrew securely.
e. Be sure and observe at least two complete
ignition and burn cycles before reinstalling the
access door.
f. Reinstall the access door.
After the dryer has operated for approximately
three minutes, exhaust air or exhaust pipe
should be warm.
For personal safety, the access door must
be in place during normal operation.
WARNING
Figure 38
D399S
AIR
SHUTTER
AIR SHUTTER
LOCKSCREW